这里是JH1000A卧式离子风机的英文翻译:
The 1000A Horizontal Ionizing Fan generates a large volume of airflow containing both positive and negative ions, which neutralizes static charges on object surfaces.
If the object surface carries a negative charge, it will attract positive ions from the airflow.
If the object surface carries a positive charge, it will attract negative ions from the airflow.
This process neutralizes static electricity, effectively eliminating electrostatic charges.
The 1000A Horizontal Ionizing Fan is equipped with an axial fan to provide airflow, and the airflow speed can be adjusted over a wide range using a speed control switch.
The ionizing component operates under high voltage and low current, creating a stable high-voltage electric field that ionizes the surrounding air. The generated ions are carried by the airflow to the object surface, neutralizing static electricity.
The ionizing component includes a specialized cleaning device, which removes dust buildup from the ionizing needles, ensuring the proper functioning of the ionizer.
The static elimination function of the 1000A Ionizing Fan helps resolve various production issues caused by static electricity, such as:
Dust attraction problems
Adhesion issues in plastic processing
Electrostatic repulsion, which causes small parts to jump or misalign
Rapid static elimination
Large ionized airflow coverage
Wide-range airflow adjustment
Stable ion balance, with an optional ion regulator if needed
Built-in ion emitter cleaning system
Equipped with an ionization indicator
Optional cooling or heating function
Optional air filter attachment
Adjustable airflow direction
Reliable grounding protection
Specification | Details |
---|---|
Power Consumption | 50W / 250W (with heating) |
Input Voltage | 220V/50Hz or 110V/60Hz |
Output Voltage | AC 5.6KV |
Ion Balance | ≤ ±10V |
Airflow | ≤ 3.3m³/min |
Effective Ionization Coverage | 590mm × 1800mm |
Ozone Emission | ≤ 0.03PPM (measured at 15cm from fan) |
Noise Level | 50dB |
Operating Temperature | 0°C – 50°C |
Dimensions | |
Without Stand | 390mm (L) × 210mm (W) × 115mm (H) |
With Stand | 450mm (L) × 210mm (W) × 190mm (H) |
Weight | Approx. 7.3kg (Net Weight) |
Housing Material | Cold-rolled steel |
Surface Treatment | Baked enamel coating |
Test Voltage: 1KV – 100V
Ambient Temperature: 22°C
Humidity: ≤ 60%
Test Distance | Left 300mm | Center | Right 300mm |
---|---|---|---|
300mm | 1.1s | 1.0s | 1.1s |
600mm | 2.2s | 2.2s | 2.2s |
📌 Notes:
The ion balance voltage and static elimination time of the JH1000A Ionizing Fan comply with ESD standards.
Static elimination time was measured using a ME268A Electrostatic Comprehensive Tester, from 1000V to 100V.
Test data may vary depending on ambient temperature and humidity.